Technolec

EDS-2016-ML SERIES

Unmanaged Ethernet switch with 16 10/100BaseT(X) ports, dual 12/24/48 power inputs, -10 to 60°C operating temperature
eds-2016-ml-series
10/100BaseT(X) (RJ45 connector), 100BaseFX (multi-mode, SC/ST connectors) Fiber models will be available in the second half of 2020.
QoS supported to process critical data in heavy traffic
Relay output warning for power failure and port break alarm
IP30-rated metal housing
Redundant dual 12/24/48 VDC power inputs
-40 to 75°C operating temperature range (-T model)

Ethernet Interface

  • 10/100BaseT(X) Ports (RJ45 connector): 16
  • Standards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service
  • 100BaseFX Ports (multi-mode SC connector): EDS-2016-ML-MM-SC: 2EDS-2016-ML-MM-SC-T: 2
  • 100BaseFX Ports (multi-mode ST connector): EDS-2016-ML-MM-ST: 2EDS-2016-ML-MM-ST-T: 2
  • 100BaseFX Ports (single-mode SC connector): EDS-2016-ML-SS-SC: 2EDS-2016-ML-SS-SC-T: 2
  • Optical Fiber: Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).
  • Optical Fiber: 100BaseFX
  • Optical Fiber: Multi-Mode
  • Optical Fiber: Single-Mode (40 km)
  • Optical Fiber: Single-Mode (80 km)
  • Optical Fiber: Fiber Cable Type
  • Optical Fiber: OM1
  • Optical Fiber: 50/125 µm
  • Optical Fiber: G.652
  • Optical Fiber: G.652
  • Optical Fiber: 800 MHz x km
  • Optical Fiber: Typical Distance
  • Optical Fiber: 4 km
  • Optical Fiber: 5 km
  • Optical Fiber: 40 km
  • Optical Fiber: 80 km
  • Optical Fiber: Wavelength
  • Optical Fiber: Typical (nm)
  • Optical Fiber: 1300
  • Optical Fiber: 1310
  • Optical Fiber: 1550
  • Optical Fiber: TX Range (nm)
  • Optical Fiber: 1260 to 1360
  • Optical Fiber: 1280 to 1340
  • Optical Fiber: 1530 to 1570
  • Optical Fiber: RX Range (nm)
  • Optical Fiber: 1100 to 1600
  • Optical Fiber: 1100 to 1600
  • Optical Fiber: 1100 to 1600
  • Optical Fiber: Optical Power
  • Optical Fiber: TX Range (dBm)
  • Optical Fiber: -10 to -20
  • Optical Fiber: 0 to -5
  • Optical Fiber: 0 to -5
  • Optical Fiber: RX Range (dBm)
  • Optical Fiber: -3 to -32
  • Optical Fiber: -3 to -34
  • Optical Fiber: -3 to -34
  • Optical Fiber: Link Budget (dB)
  • Optical Fiber: 12
  • Optical Fiber: 29
  • Optical Fiber: 29
  • Optical Fiber: Dispersion Penalty (dB)
  • Optical Fiber: 3
  • Optical Fiber: 1
  • Optical Fiber: 1
  • Optical Fiber: Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

DIP Switch Configuration

  • Ethernet Interface: Quality of Service (QoS) Broadcast storm protection Port break alarm

Input/Output Interface

  • Alarm Contact Channels: Relay output with current carrying capacity of 1 A @ 24 VDC

Switch Properties

  • MAC Table Size: 8 K
  • Packet Buffer Size: 2 Mbits
  • Processing Type: Store and Forward

Power Parameters

  • Connection: 1 removable 6-contact terminal block(s)
  • Input Current: 0.088 A @ 24 VDC
  • Input Voltage: 12/24/48 VDC Redundant dual inputs
  • Operating Voltage: 9.6 to 60 VDC
  • Overload Current Protection: Supported
  • Reverse Polarity Protection: Supported

Physical Characteristics

  • Housing: Metal
  • IP Rating: IP30
  • Dimensions: 36 x 135 x 95 mm (1.41 x 5.31 x 3.74 in)
  • Weight: 486 g (1.07 lb)
  • Installation: DIN-rail mounting Wall mounting (with optional kit)

Environmental Limits

  • Operating Temperature: -10 to 60°C (14 to 140°F)
  • Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications

  • Safety: UL 61010-2-201 EN 62368-1(LVD)
  • EMC: EN 55032/35 EN 61000-6-2/-6-4
  • EMI: CISPR 32, FCC Part 15B Class A
  • EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
  • Railway: EN 50121-4
  • Vibration: IEC 60068-2-6
  • Shock: IEC 60068-2-27
  • Freefall: IEC 60068-2-32
  • Hazardous Locations: Class I Division 2 ATEX IECEx
  • Maritime: DNV LR ABS NK
  • Traffic Control: NEMA TS2

MTBF

  • Time: 2,523,953 hrs
  • Standards: Telcordia (Bellcore), GB

Warranty

  • Warranty Period: 5 years
  • Details: See www.moxa.com/warranty

Available Models

Model No. Description Quantity
EDS-2016-ML-SS-SC-T Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX single-mode ports with SC connectors, -40 to 75°C operating temperature
EDS-2016-ML-MM-SC-T Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX multi-mode ports with SC connectors, -40 to 75°C operating temperature
EDS-2016-ML-MM-ST-T Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX multi-mode ports with ST connectors, -40 to 75°C operating temperature
EDS-2016-ML-T Unmanaged Ethernet switch with 16 10/100BaseT(X) ports, dual 12/24/48 power inputs, -40 to 75°C operating temperature
EDS-2016-ML-SS-SC Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX single-mode ports with SC connectors, -10 to 60°C operating temperature
EDS-2016-ML-MM-SC Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX multi-mode ports with SC connectors, -10 to 60°C operating temperature
EDS-2016-ML Unmanaged Ethernet switch with 16 10/100BaseT(X) ports, dual 12/24/48 power inputs, -10 to 60°C operating temperature
EDS-2016-ML-MM-ST Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 2 100BaseFX multi-mode ports with ST connectors, -10 to 60°C operating temperature