TCF-142 SERIES
RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and SC connector, 0 to 60°C operating temperature
Ring and point-to-point transmission
Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF-142-S) or 5 km with multi-mode (TCF-142-M)
Decreases signal interference
Protects against electrical interference and chemical corrosion
Supports baudrates up to 921.6 kbps
Wide-temperature models available for -40 to 75°C environments
Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF-142-S) or 5 km with multi-mode (TCF-142-M)
Decreases signal interference
Protects against electrical interference and chemical corrosion
Supports baudrates up to 921.6 kbps
Wide-temperature models available for -40 to 75°C environments
Serial Interface
- No. of Ports: 2
- Serial Standards: RS-232 RS-422 RS-485
- Baudrate: 50 bps to 921.6 kbps (supports non-standard baudrates)
- Flow Control: ADDC (automatic data direction control) for RS-485
- Optical Fiber: 1
- Optical Fiber: Low-Speed Fiber Module
- Optical Fiber: Multi-Mode
- Optical Fiber: Single-Mode
- Optical Fiber: Fiber Cable Requirements
- Optical Fiber: 50/125 µm, 800 MHz
- Optical Fiber: G.652
- Optical Fiber: 62.5/125 µm, 500 MHz
- Optical Fiber: Typical Distance
- Optical Fiber: 5 km
- Optical Fiber: 40 km
- Optical Fiber: Wavelength
- Optical Fiber: Typical (nm)
- Optical Fiber: 850
- Optical Fiber: 1310
- Optical Fiber: TX Range (nm)
- Optical Fiber: 840 to 860
- Optical Fiber: 1290 to 1330
- Optical Fiber: RX Range (nm)
- Optical Fiber: 800 to 900
- Optical Fiber: 1100 to 1650
- Optical Fiber: Optical Power
- Optical Fiber: TX Range (dBm)
- Optical Fiber: 0 to -5
- Optical Fiber: 0 to -5
- Optical Fiber: RX Range (dBm)
- Optical Fiber: 0 to -20
- Optical Fiber: 0 to -25
- Optical Fiber: Link Budget (dB)
- Optical Fiber: 15
- Optical Fiber: 20
- Optical Fiber: Dispersion Penalty (dB)
- Optical Fiber: 1
- Optical Fiber: 1
- Optical Fiber: Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, ..., 0h) to the serial converter’s serial port.
- Pull High/Low Resistor for RS-485: 1 kilo-ohm, 150 kilo-ohms
- RS-485 Data Direction Control: ADDC (automatic data direction control)
- Terminator for RS-485: N/A, 120 ohms, 120 kilo-ohms
- Connector: Multi-mode SC connector
- Latency: 300 ns
Serial Signals
- RS-232: TxD, RxD, GND
- RS-422: Tx+, Tx-, Rx+, Rx-, GND
- RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
- RS-485-2w: Data+, Data-, GND
Power Parameters
- No. of Power Inputs: 1
- Input Current: 70 to 140 mA @ 12 to 48 VDC
- Input Voltage: 12 to 48 VDC
- Overload Current Protection: Supported
- Power Connector: Terminal block
- Power Consumption: 70 to 140 mA @ 12 to 48 VDC
- Reverse Polarity Protection: Supported
Physical Characteristics
- IP Rating: IP30
- Housing: Metal
- Dimensions (with ears): 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
- Dimensions (without ears): 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
- Weight: 320 g (0.71 lb)
- Installation: Wall mounting
Environmental Limits
- Operating Temperature: 0 to 60°C (32 to 140°F)
- Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
- EMC: EN 55032/35
- EMI: CISPR 32, FCC Part 15B Class A
- EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 PFMF
- Environmental Testing: IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3
- Safety: UL 60950-1
- Vibration: IEC 60068-2-6
MTBF
- Time: 780,480 hrs
- Standards: Telcordia (Bellcore), GB
Warranty
- Warranty Period: 5 years
- Details: See www.moxa.com/warranty